Industry-Preferred Two-Chamber Cryogenic Freezing Bags

Intended Use: The OriGen Biomedical® CryoStore 25 bags are intended to freeze blood components.

Registration

FDA 510(k) Cleared. CE Marked.

OriGen Biomedical sells directly and works with a network of global distributors. For availability in your country, please contact us below.

  • Protect Your Cells

    Hermetically sealed spike ports in each chamber provide a tamper-proof design. The EVA film used in every CryoStore bag is biologically safe for its use, and its durability has been proven through validation and customer success.

  • Traceability

    The CryoStore 25 Freezing Bag has a printed number on each chamber for easy identification. The numbers on the chambers match the pre-marked printed segments, which hold approximately 100µl of cell product. This can aid in tracing aliquot samples to the bag.

  • User Inspired Design

    Stock tubing sets may include luer-activated needle-free valves, sterile-weldable tubing, roller clamps, and/or luer connectors. The donor tube is placed in the corner of each bag for easier de-bubbling and sealing.

  • Closed System Processing

    OriGen provides products that enable the user to manipulate cellular products in a closed system, reducing the risk of contamination.

ML59.R03

Interested in the CryoStore 25 Freezing Bag?

Contact us today to get a price quote or sample products.

Contact Us

Product Use

Product Code

Description

Tube Set Description

Case Qty

 

CS25F CryoStore 25 EVA Freezing Bag, 10 – 25ml, “F” Tube Set Female luer with cap 24  
CS25FP CryoStore 25 EVA Freezing Bag, 10 – 25ml, “F” Tube Set, singly packed Female luer with caps 12

Special Order

CS25N CryoStore 25 EVA Freezing Bag, 10 – 25ml, “N” Tube Set One male luer with cap, two female luers with caps, and a needle-free injection port 24  
CS25NS CryoStore 25 EVA Freezing Bag, 10 – 25ml, “N” Tube Set, double aseptically packed One male luer with cap, two female luers with caps, and a needle-free injection port 12  
CS25NSW CryoStore 25 EVA Freezing Bag, 10 – 25ml, “N” Tube Set, double aseptically packed in OW One male luer with cap, two female luers with caps, and a needle-free injection port 12  
CS25XN CryoStore 25 EVA Freezing Bag, 10 – 25ml, “N” Tube Set, 8″ donor tube One male luer with cap, two female luers with caps, and a needle-free injection port 24

Special Order

CS25Y4 CryoStore 25 EVA Freezing Bag, 10 – 25ml, “Y4” Tube Set One spike, one male luer with cap and 50cm SCD Tube with a needle-free injection port and pinch clamp 24

Special Order

Will freezing bags break or fracture when impacted, dropped, etc. while frozen?

All plastics have a glass transition temperature unique to the identity and grade of the polymer that makes up the plastic. OriGen Biomedical products have a glass transition temperature between -65°C to -150°C. Above this temperature, the bags are flexible. However, once the bag is cooled below its glass transition temperature (our products can be frozen down to -196°C), the films lose their plasticity. Any impact, pinch, cut, etc. can result in a clean fracture that radiates from the point of impact, akin to broken glass. Please see our white paper on How to Prevent Freezing Bag Breaks for more information.

What are the dimensions of a particular CryoStore Bag?

The overall bag footprint is 9.0cm wide x 7.4cm long.

What is the expiration date of CryoStore Products?

CryoStore Bags and Accessory Sets: 4 years from sterilization

What do the product codes mean?

Please see our product code definitions located here.

What is the total fill volume of the CryoStore 25 Freezing Bag?

Assuming the bag is filled to the max capacity of 25mL, and the small chamber holds 2-4mL, the large chamber would have 21-23mL.

Is the CryoStore tubing weldable?

For the standard tubeset, the tubing between the Y-component and the luers is PVC and is weldable.

For the ‘N’ tube set, the tubing between the Y-component and the luers is PVC and is weldable. The tubing from the NFV to Y-component is also PVC, but has a different diameter, which is not weldable to standard tubing.

For other tube sets, please reference the Technical Data Sheets to determine the material of the tubing present and its compatibility with welding.

For all CryoStore bags, the printed tubing is co-extruded EVA/PVC. This section of tubing is sealable, but not weldable.

How do I obtain pricing?

Please contact your OriGen Account Manager (USA, Canada, or UK), your local distributor (international), or OriGen Biomedical if you are unsure of who to contact through the form here or by calling +1-512-474-7278.

What cell types/lines can CryoStore bags be used with?

CryoStore bags are not specific to any one cell line. They are intended to provide protection during cryopreservation for blood components. Users should validate specific blood or blood components per their institutional protocols.

What are OriGen's lead times?

When available, most orders ship within 2-3 business days. Some international orders may take 3-5 business days for shipment. Special order items will always be manufactured to order, with minimum quantities and a lead time.

Are CryoStore bags designed to be frozen inside liquid nitrogen, vapor phase, or both?

CryoStore bags are validated to maintain integrity in direct liquid nitrogen and are therefore able to be frozen at temperatures found in both in liquid and in vapor phases. Please follow institutional protocols to determine the phase of nitrogen that best suits your needs.

What applications could CryoStore 25 Freezing Bags be used in?

OriGen does not indicate the CryoStore bags for specific applications. The patient group is not a factor in the clinical use of the CryoStore Freezing Bags as the products are not intended for use with any specific patient population, disease state, clinical stage of disease, nor patient condition. Our existing customers commonly use the CryoStore bags for:
• Cell Therapy and Gene Therapy
• Regenerative Medicine
• Immuno-oncology
• Personalized Medicine
• Research and Development
• Storage and Shipping of Biological Materials

What is the recommended storage for CryoStore Freezing Bags?

Store in a cool, dry area (typically 15°C – 30°C), but users should define and validate their specific space and assign ranges suitable for their conditions.

What is "double aseptically packed"?

All products that are labeled “double aseptically packed” are delivered with each device packaged individually inside two sterile barrier pouches. Product codes with in an ‘S’ indicate that they are double aseptically packed.

What cassettes can be used with CryoStore Freezing Bags?

OriGen Biomedical CryoStore bags have been manufactured to fit inside most standard cassette sizes. Please refer to the cassette manufacturer for details.

Are CryoStore tube sets DMSO-resistant?

All components currently used in OriGen Biomedical product lines are rated for exposure to solutions containing a concentration of 80% DMSO or less. If using DMSO, dilute to less than 60% concentration before use.

I have a problem with a product, what is the complaint procedure?

If you encounter any issues with an OriGen Biomedical product and wish to file a complaint, we encourage you to do so ASAP. Please contact the OriGen head office or reach out to your dedicated sales representative for assistance. To facilitate our investigation and resolution process, we kindly ask that you retain both the product and its packaging. This will aid us in conducting a thorough analysis of the matter. All complaints will be acknowledged, and OriGen will follow up as appropriate during the investigation. Your feedback is invaluable to us as we strive to maintain the highest standards of quality and customer satisfaction.

How do I report an adverse event?

Any adverse event related to the device should immediately be reported to OriGen Biomedical or its authorized distributor, the competent local authority, and any other regulators as required by telephone, fax, or letter. This includes an incident or risk of a serious incident liable to result in, or to have resulted in, the death or serious deterioration in the health condition of a patient or user. All complaints should be accompanied by the name(s), reference(s), and batch number(s) of the component(s) and the name and address of the claimant, the nature of the complaint with as much detail as possible, and the indication of a requested response. OriGen Biomedical is located at 2215 Grand Avenue Parkway, Austin, TX, USA 78728-3812 (Tel: +1-512-474-7278, Email: sales.us@origen.com).

Where can I find the Instructions for Use (IFU), Certificate of Analysis (CoA), Certificate of Conformance (CoC), and/or Safety Data Sheet (SDS) for the product I received?

OriGen has transitioned to using Electronic Instructions for Use (eIFUs). They are available at ifu.origen.com. Your CoA or CoC will be included with your original shipment box and can also be accessed through the Client Login. If you do not have a current Client Login, you will need to register for an account to access these documents.

How can I remove air bubbles from the CryoStore 25 Bag?

OriGen recommends connecting a syringe to the needle-free valve to remove the air from the bags. Customers can gently manipulate and massage the bag to move the air to the top of the bag near the ports. The bag may need to be tilted to get the air to move near the port and then the user can pull out the air using the syringe.

What particulate matter testing is performed and what is the acceptance criteria?

Your account representative can provide you with a detailed summary of particulate inspections performed on OriGen Biomedical® products [TCL03]. Please reach out to them directly.

How much air is acceptable to be left in the bag when undergoing cryopreservation?

OriGen recommends removing as much air as possible since multiple small air bubbles can combine and form one large air bubble. If air is left in the bag, the air can rapidly expand and the pressure can result in bag breaks. We do not have a quantitative amount of air defined as acceptable within the bag and recommend users follow their institutional protocols and validate their processes.

What cleaning solutions can be used with OriGen Biomedical products?

OriGen uses 70% IPA in our production environment, including wiping S-F10 accessory sets. There are no expected adverse impacts to using a wipe moistened with 70% IPA to wipe the sets. We have not validated that 70% IPA disinfects the sets.

What are your pouching materials?

Our pouches are made of Tyvek (white side) and PET/LDPE (clear side).

Is it okay to use the CryoStore Freezing Bag if some of the components have changed color?

Some of the plastic components discolor overtime due to the gamma radiation used in sterilization. This is expected and has been show to not affect the performance of the device. However, please report a complaint to OriGen if something discolors differently than expected. For example, if there is a large difference in color/shade between similar components in the same lot, similar components in different lots, or components within the same packaging.

Special order items will always be manufactured to order – plan for minimum quantities and extended lead times.

Interested in Custom Product Development?

Learn more about the custom product development process by clicking below.

Learn More