Industry-Preferred Cryogenic Freezing Bags

Intended Use: The OriGen Biomedical® CryoStore bags are intended to freeze blood components.

Registration

FDA 510(k) Cleared. CE Marked.

OriGen Biomedical sells directly and works with a network of global distributors. For availability in your country, please contact us below.

  • Protect Your Cells

    Hermetically sealed spike ports provide a tamper-proof design. The EVA film used in every CryoStore bag is biologically safe for its use, and its durability has been proven through validation and customer success.

  • Traceability

    A permanent lot number* is heat welded into the tail of each bag. Each** bag has a donor tube with printed segments of approximately 100uL that match the printed number on the bag.

  • User Inspired Design

    Stock tubing sets may include luer-activated needle-free valves, sterile-weldable tubing, roller clamps, and/or luer connectors. The donor tube is placed in the corner of each bag for easier de-bubbling and sealing.

  • Closed System Processing

    OriGen provides products that enable the user to manipulate cellular products in a closed system, reducing the risk of contamination.

* Permanent lot number is not the same as the OriGen production lot number on the pouch or case. │ ** Except 1000 and 2000 size bags.

ML34.R08

Interested in the CryoStore Freezing Bag?

Contact us today to get a price quote or sample products.

Contact Us

Product Use

Product Code

Description

Tube Set Description

Case Qty

 

CS50 CryoStore 50 EVA Freezing Bag, 10 – 30ml, “Standard” Tube Set Two female luers with caps 24  
CS50M3 CryoStore 50 EVA Freezing Bag, 10 – 30ml, “M3” Tube Set One male luer with cap, two female luers with caps, a needle-free injection port and a pinch clamp 24

Special Order

CS50N CryoStore 50 EVA Freezing Bag, 10 – 30ml,  “N” Tube Set One male luer with cap, two female luers with caps, and a needle-free injection port 24  
CS50NS CryoStore 50 EVA Freezing Bag, 10 – 30ml, “N” Tube Set, double aseptically packed One male luer with cap, two female luers with caps, and a needle-free injection port 12  
CS50S CryoStore 50 EVA Freezing Bag, 10 – 30ml, “Standard” Tube Set, double aseptically packed Two female luers with caps 12  
CS50V7 CryoStore multiple bag set, ten 50 EVA freezing bags, 10- 30 ml, and one 750 EVA freezing bag, 80-190ml, “V7” Tube Set Female luers with caps, “Y” connectors, pinch clamps, slide clamps, co-extruded EVA/PVC tubing and a 30 cm PVC tube 1

Special Order

CS250 CryoStore 250 EVA Freezing Bag, 30 – 70ml, “Standard” Tube Set Two female luers with caps 24  
CS250N CryoStore 250 EVA Freezing Bag, 30 – 70ml,  “N” Tube Set One male luer with cap, two female luers with caps, and a needle-free injection port 24  
CS250NS CryoStore 250 EVA Freezing Bag, 30 – 70ml,  “N” Tube Set, double aseptically packed One male luer with cap, two female luers with caps, and a needle-free injection port 12  
CS250NSW CryoStore 250 EVA Freezing Bag, 30 – 70ml,  “N” Tube Set, double aseptically packed in OW One male luer with cap, two female luers with caps, and a needle-free injection port 12  
CS250S CryoStore 250 EVA Freezing Bag, 30 – 70ml, “Standard” Tube Set, double aseptically packed, one bag Two female luers with caps 12

Special Order

CS500 CryoStore 500 EVA Freezing Bag, 55 – 100ml, “Standard” Tube Set Two female luers with caps 24  
CS500i3 CryoStore 500 EVA Freezing Bag, 55 -100ml, custom length 7.5 inches, “Standard” Tubing Set Two female luers with roller clamps 24

Special Order

CS500N CryoStore 500 EVA Freezing Bag, 55 – 100ml,  “N” Tube Set One male luer with cap, two female luers with caps, and a needle-free injection port 24  
CS500NS CryoStore 500 EVA Freezing Bag, 55 – 100ml,  “N” Tube Set, double aseptically packed One male luer with cap, two female luers with caps, and a needle-free injection port 12  
CS500NSW CryoStore 500 EVA Freezing Bag, 55 – 100ml,  “N” Tube Set, double aseptically packed in OW One male luer with cap, two female luers with caps, and a needle-free injection port 12   
CS500V2 Custom CryoStore 500 EVA 2-Bag set with spikes, 55-100ml, “V2” Tube Set, 2 sets per pouch One nylon spike with cover, one male luer with cap, a needle-free injection port and pinch clamps 12 

Special Order

CS750 CryoStore 750 EVA Freezing Bag, 80 – 190ml, “Standard” Tube Set Two female luers with caps 24  
CS750N CryoStore 750 EVA Freezing Bag, 80 – 190ml,  “N” Tube Set One male luer with cap, two female luers with caps, and a needle-free injection port 24  
CS750NS CryoStore 750 EVA Freezing Bag, 80 – 190ml, “N” Tube Set, double aseptically packed One male luer with cap, two female luers with caps, and a needle-free injection port 12  
CS750NSW CryoStore 750 EVA Freezing Bag, 80 – 190ml, “N” Tube Set, double aseptically packed in OW One male luer with cap, two female luers with caps, and a needle-free injection port 12  
CS1000N CryoStore 1000 EVA Freezing Bag, 120 – 275ml,  “N” Tube Set One male luer with cap, two female luers with caps, and a needle-free injection port with roller clamps 24  
CS2000N CryoStore 2000 EVA Freezing Bag, 180 – 450ml freezing volume, “N” Tube Set One male luer with cap, two female luers with caps, and a needle-free injection port 24  
CS2000NS CryoStore 2000 EVA Freezing Bag, 180 – 450ml freezing volume, “N” Tube Set double aseptically packed One male luer with cap, two female luers with caps, and a needle-free injection port 12

Special Order

Best viewed on a desktop or laptop computer.

Will freezing bags break or fracture when impacted, dropped, etc. while frozen?

All plastics have a glass transition temperature unique to the identity and grade of the polymer that makes up the plastic. OriGen Biomedical products have a glass transition temperature between -65°C to -150°C. Above this temperature, the bags are flexible. However, once the bag is cooled below its glass transition temperature (our products can be frozen down to -196°C), the films lose their plasticity. Any impact, pinch, cut, etc. can result in a clean fracture that radiates from the point of impact, akin to broken glass. Please see our white paper on How to Prevent Freezing Bag Breaks for more information.

What are the dimensions of a particular CryoStore Bag?

All sizing information can be found on the product brochure.

What is the expiration date of CryoStore Products?

CryoStore Bags and Accessory Sets: 4 years from sterilization

What do the product codes mean?

Please see our product code definitions located here.

What is the total fill volume of the CryoStore Freezing Bag?

All fill volume information can be found on the product brochure.

How do I obtain pricing?

Please contact your OriGen Account Manager (USA, Canada, Ireland, or UK), your local distributor (international), or OriGen Biomedical if you are unsure of who to contact through the form here or by calling +1-512-474-7278.

In what environment are the bags assembled in?

All assembly, including tube sets and the bag sealing, occurs in an ISO 14644 Class 7 cleanroom.

What cell types/lines can CryoStore bags be used with?

CryoStore bags are not specific to any one cell line. They are intended to provide protection during cryopreservation for blood components. Users should validate specific blood or blood components per their institutional protocols.

Is the CryoStore tubing weldable?

For the standard tubeset, the tubing between the Y-component and the luers is PVC and is weldable.

For the ‘N’ tube set, the tubing between the Y-component and the luers is PVC and is weldable. The tubing from the NFV to Y-component is also PVC, but has a different diameter, which is not weldable to standard tubing.

For other tube sets, please reference the Technical Data Sheets to determine the material of the tubing present and its compatibility with welding.

For all CryoStore bags, the printed tubing is co-extruded EVA/PVC. This section of tubing is sealable, but not weldable.

Are CryoStore bags designed to be frozen inside liquid nitrogen, gas phase, or both?

CryoStore bags are validated to maintain integrity in direct liquid nitrogen and are therefore able to be frozen at temperatures found in both in liquid and in vapor phases. Please follow institutional protocols to determine the phase of nitrogen that best suits your needs.

What are OriGen's lead times?

When available, most orders ship within 2-3 business days. Some international orders may take 3-5 business days for shipment. Special order items will always be manufactured to order, with minimum quantities and a lead time.

What applications could CryoStore Freezing Bags be used in?

OriGen does not indicate the CryoStore bags for specific applications. The patient group is not a factor in the clinical use of the CryoStore Freezing Bags as the products are not intended for use with any specific patient population, disease state, clinical stage of disease, nor patient condition. Our existing customers commonly use the CryoStore bags for:
• Cell Therapy and Gene Therapy
• Regenerative Medicine
• Immuno-oncology
• Personalized Medicine
• Research and Development
• Storage and Shipping of Biological Materials

What is the recommended storage for CryoStore Freezing Bags?

Store in a cool, dry area (typically 15°C – 30°C), but users should define and validate their specific space and assign ranges suitable for their conditions.

What conformances do CryoStore Freezing Bags meet?

OriGen Biomedical maintains a quality management system in conformity with ISO 13485 and applicable regulatory requirements, including U.S. FDA 21 CFR and the EU Medical Device Regulation (EU MDR), and is audited under the Medical Device Single Audit Program (MDSAP). Risk management activities are conducted in accordance with ISO 14971. As applicable to CryoStore, product and process controls, testing, evaluation, packaging, sterilization, labeling, biocompatibility, and environmental controls incorporate applicable requirements and/or methods from ISO 11137, ISO 11607, ISO 15223, ISO 20417, ISO 11737, ISO 10993, and ISO 14644.

What is "double aseptically packed"?

All products that are labeled “double aseptically packed” are delivered with each device packaged individually inside two sterile barrier pouches. Product codes with in an ‘S’ at the end indicate that they are double aseptically packed.

What cassettes can be used with CryoStore Freezing Bags?

OriGen Biomedical CryoStore bags have been manufactured to fit inside most standard cassette sizes. Please refer to the cassette manufacturer for details.

Are CryoStore tube sets DMSO-resistant?

All components currently used in OriGen Biomedical product lines are rated for exposure to solutions containing a concentration of 80% DMSO or less. If using DMSO, dilute to less than 60% concentration before use.

I have a problem with a product, what is the complaint procedure?

If you encounter any issues with an OriGen Biomedical product and wish to file a complaint, we encourage you to do so ASAP. Please contact the OriGen head office or reach out to your dedicated sales representative for assistance. To facilitate our investigation and resolution process, we kindly ask that you retain both the product and its packaging. This will aid us in conducting a thorough analysis of the matter. All complaints will be acknowledged, and OriGen will follow up as appropriate during the investigation. Your feedback is invaluable to us as we strive to maintain the highest standards of quality and customer satisfaction.

How do I report an adverse event?

Any adverse event related to the device should immediately be reported to OriGen Biomedical or its authorized distributor, the competent local authority, and any other regulators as required by telephone, fax, or letter. This includes an incident or risk of a serious incident liable to result in, or to have resulted in, the death or serious deterioration in the health condition of a patient or user. All complaints should be accompanied by the name(s), reference(s), and batch number(s) of the component(s) and the name and address of the claimant, the nature of the complaint with as much detail as possible, and the indication of a requested response. OriGen Biomedical is located at 2215 Grand Avenue Parkway, Austin, TX, USA 78728-3812 (Tel: +1-512-474-7278, Email: sales.us@origen.com).

Where can I find the Instructions for Use (IFU), Certificate of Analysis (CoA), Certificate of Conformance (CoC), and/or Safety Data Sheet (SDS) for the product I received?

OriGen has transitioned to using Electronic Instructions for Use (eIFUs). They are available at ifu.origen.com. Your CoA or CoC will be included with your original shipment box and can also be accessed through the Client Login. If you do not have a current Client Login, you will need to register for an account to access these documents.

What particulate matter testing is performed and what is the acceptance criteria?

Your account representative can provide you with a detailed summary of particulate inspections performed on OriGen Biomedical® products [TCL03]. Please reach out to them directly.

How much air is acceptable to be left in the bag when undergoing cryopreservation?

OriGen recommends removing as much air as possible since multiple small air bubbles can combine and form one large air bubble. If air is left in the bag, the air can rapidly expand and the pressure can result in bag breaks. We do not have a quantitative amount of air defined as acceptable within the bag and recommend users follow their institutional protocols and validate their processes.

What cleaning solutions can be used with OriGen Biomedical products?

OriGen uses 70% IPA in our production environment. There are no expected adverse impacts to using a wipe moistened with 70% IPA to wipe the sets. We have not validated that 70% IPA disinfects the sets.

How can I remove air bubbles from the CryoStore Bag?

OriGen recommends connecting a syringe to the needle-free valve to remove the air from the bags. Customers can gently manipulate and massage the bag to move the air to the top of the bag near the ports. The bag may need to be tilted to get the air to move near the port and then the user can pull out the air using the syringe.

What are your pouching materials?

Our pouches are made of Tyvek (white side) and PET/LDPE (clear side).

Is it okay to use the CryoStore Freezing Bag if some of the components have changed color?

Some of the plastic components discolor overtime due to the gamma radiation used in sterilization. This is expected and has been show to not affect the performance of the device. However, please report a complaint to OriGen if something discolors differently than expected. For example, if there is a large difference in color/shade between similar components in the same lot, similar components in different lots, or components within the same packaging.

Damodharan SN, Walker KL, Forsberg MH, et al. Analysis of ex vivo expanded and activated clinical grade human NK cells after cryopreservation. Cytotherapy, 22(8):450-457, 11 Jun 2020. PMID: 32536506

Kilbride P, Meneghel J, Creasey G, et al. Automated dry thawing of cryopreserved haematopoietic cells is not adversely influenced by cryostorage time, patient age or gender. PLoS One, 15(10):e0240310, 26 Oct 2020. PMID: 33104704

Setia RD, Arora S, Handoo A, et al. Outcome of 51 autologous peripheral blood stem cell transplants after uncontrolled-rate freezing (“dump freezing”) using -80°C mechanical freezer. Asian J Transfus Sci, 12(2):117-122, 01 Jul 2018. PMID: 30692795.

F Aerts-Kaya, G Koca, P Sharafi, , et al. Automated washing of long-term cryopreserved peripheral blood stem cells promotes cell viability and preserves CD34+ cell numbers. Bone Marrow Transplantation. Volume 53, pages 1225–1227 (2018).

Huang J, Khan A, Au BC, Barber DL, et al. Lentivector Iterations and Pre-Clinical Scale-Up/Toxicity Testing: Targeting Mobilized CD34+ Cells for Correction of Fabry Disease. Mol Ther Methods Clin Dev, 5:241-258, 12 May 2017. PMID: 28603745

Morello, W., Budelli, S., Bernstein, D. A., Montemurro, T., Montelatici, E., Lavazza, C., … & Montini, G. (2022). First clinical application of cord blood mesenchymal stromal cells in children with multi-drug resistant nephrotic syndrome. Stem Cell Research & Therapy, 13(1), 1-9.

Special order items will always be manufactured to order – plan for minimum quantities and extended lead times.

Interested in Custom Product Development?

Learn more about the custom product development process by clicking below.

Learn More