Industry-Preferred Cryogenic Freezing Bags Transforming Future Possibilities

Intended Use: The OriGen Biomedical® CryoStore FLEX bags are intended to freeze blood components.

Registration

FDA 510(k) Cleared. CE Marked.

OriGen Biomedical sells directly and works with a network of global distributors. For availability in your country, please contact us below.

  • Flexibility

    The CryoStore FLEX Bag can be filled and sealed into separate 4-6ml chambers for flexible utilization post-thaw. Depending on the number of cells a patient needs, a variable number of compartments can be utilized. The FLEX bag is designed for scalable dosing, and the bag segments can be used to increase doses incrementally.

  • Durability

    The CryoStore FLEX Bag is made of the same robust EVA material as our existing industry-preferred OriGen Biomedical CryoStore Bags, known for their durability proven through validation and customer success.

  • Representative

    Cell products frozen into the CryoStore FLEX bag will be contacting the same materials at similar freeze thicknesses as cell products frozen in larger CryoStore bags. The FLEX bag is a representative sample of the contents of a CryoStore final cell product bag that can be used for quality assurance testing and dosing.

  • Less Equipment

    FLEX Bags fit into the same size cassette as a CryoStore CS50 bag allowing for cold storage next to the final product and eliminating the need for cryovials and cold vial storage. It can be stored in the same rack and same tank as the final cell product.

ML58.R02

Interested in the CryoStore FLEX Bag?

Contact us today to get a price quote or sample products.

Contact Us

Product Use

Product Code

Product Description

Packaging

Case Qty

CS20N N” Tube Set – One male luer with cap, two female luers with caps, roller clamps, and a needle-free injection port Pouch of 4 24
CS20NS N” Tube Set – One male luer with cap, two female luers with caps, roller clamps, and a needle-free injection port

Pouch of 1

(double aseptically packed)

12
CS20F “F” Tube Set – One female luer with cap and pinch clamp Pouch of 4 24
CS20V6 Multiple bag set, six CS20 EVA freezing bags, “V6” Tube Set – “Y” connectors, pinch clamps, 60ml syringe, stop cock, and 60cm PVC tube terminated with an NFV Pouch of 1 set 5

Will freezing bags break or fracture when impacted, dropped, etc. while frozen?

All plastics have a glass transition temperature unique to the identity and grade of the polymer that makes up the plastic. OriGen Biomedical products have a glass transition temperature between -65°C to -150°C. Above this temperature, the bags are flexible. However, once the bag is cooled below its glass transition temperature (our products can be frozen down to -196°C), the films lose their plasticity. Any impact, pinch, cut, etc. can result in a clean fracture that radiates from the point of impact, akin to broken glass. Please see our white paper on How to Prevent Freezing Bag Breaks for more information.

What is the freeze/fill volume of the CryoStore FLEX Bag?

Freeze/Fill Volume per Chamber = 4-6ml
Freeze/Fill Volume per Bag = 20-30ml

What is the expiration date of CryoStore Products?

4 years from sterilization

What do the product codes mean?

Please see our product code definitions located here.

What are the dimensions of individual chambers?

~2.4″ in height and ~0.8″ wide

Is the CryoStore tubing weldable?

For the ‘N’ tube set, the tubing between the Y-component and the luers is PVC and is weldable. The tubing from the NFV to Y-component is also PVC, but has a different diameter, which is not weldable to standard tubing.

For other tube sets, please reference the Technical Data Sheets to determine the material of the tubing present and its compatibility with welding.

How do I obtain pricing?

Please contact your OriGen Account Manager (USA, Canada, or UK), your local distributor (international), or OriGen Biomedical if you are unsure of who to contact through the form here or by calling +1-512-474-7278.

What cell types/lines can CryoStore bags be used with?

CryoStore bags are not specific to any one cell line. They are intended to provide protection during cryopreservation for blood components. Users should validate specific blood or blood components per their institutional protocols.

What are OriGen's lead times?

When available, most orders ship within 2-3 business days. Some international orders may take 3-5 business days for shipment. Special order items will always be manufactured to order, with minimum quantities and a lead time.

Are CryoStore bags designed to be frozen inside liquid nitrogen, gas phase, or both?

CryoStore bags are validated to maintain integrity in direct liquid nitrogen and are therefore able to be frozen at temperatures found in both in liquid and in vapor phases: -196°C (-321°F). Please follow institutional protocols to determine the phase of nitrogen that best suits your needs.

What applications could CryoStore FLEX Bags be used in?

OriGen does not indicate the CryoStore bags for specific applications. The patient group is not a factor in the clinical use of the CryoStore Freezing Bags as the products are not intended for use with any specific patient population, disease state, clinical stage of disease, nor patient condition. Our existing customers commonly use the CryoStore bags for:
• Cell Therapy and Gene Therapy
• Regenerative Medicine
• Immuno-oncology
• Personalized Medicine
• Research and Development
• Storage and Shipping of Biological Materials

What is the recommended storage for CryoStore FLEX Bags?

Store in a cool, dry area (typically 15°C – 30°C), but users should define and validate their specific space and assign ranges suitable for their conditions. Do not use if the product is damaged. Do not re-sterilize. For single use only.

What is "double aseptically packed"?

All products that are labeled “double aseptically packed” are delivered with each device packaged individually inside two sterile barrier pouches. Product codes with in an ‘S’ indicate that they are double aseptically packed.

What cassettes can be used with CryoStore Freezing Bags?

OriGen Biomedical CryoStore bags have been manufactured to fit inside most standard cassette sizes. Please refer to the cassette manufacturer for details.

Are CryoStore tube sets DMSO-resistant?

All components currently used in OriGen Biomedical product lines are rated for exposure to solutions containing a concentration of 80% DMSO or less. If using DMSO, dilute to less than 60% concentration before use.

I have a problem with a product, what is the complaint procedure?

If you encounter any issues with an OriGen Biomedical product and wish to file a complaint, we encourage you to do so ASAP. Please contact the OriGen head office or reach out to your dedicated sales representative for assistance. To facilitate our investigation and resolution process, we kindly ask that you retain both the product and its packaging. This will aid us in conducting a thorough analysis of the matter. All complaints will be acknowledged, and OriGen will follow up as appropriate during the investigation. Your feedback is invaluable to us as we strive to maintain the highest standards of quality and customer satisfaction.

How do I report an adverse event?

Any adverse event related to the device should immediately be reported to OriGen Biomedical or its authorized distributor, the competent local authority, and any other regulators as required by telephone, fax, or letter. This includes an incident or risk of a serious incident liable to result in, or to have resulted in, the death or serious deterioration in the health condition of a patient or user. All complaints should be accompanied by the name(s), reference(s), and batch number(s) of the component(s) and the name and address of the claimant, the nature of the complaint with as much detail as possible, and the indication of a requested response. OriGen Biomedical is located at 2215 Grand Avenue Parkway, Austin, TX, USA 78728-3812 (Tel: +1-512-474-7278, Email: sales.us@origen.com).

Where can I find the Instructions for Use (IFU), Certificate of Analysis (CoA), Certificate of Conformance (CoC), and/or Safety Data Sheet (SDS) for the product I received?

OriGen has transitioned to using Electronic Instructions for Use (eIFUs). They are available at ifu.origen.com. Your CoA or CoC will be included with your original shipment box and can also be accessed through the Client Login. If you do not have a current Client Login, you will need to register for an account to access these documents.

How can I remove air bubbles from the CryoStore FLEX Bag?

OriGen recommends connecting a syringe to the needle-free valve to remove the air from the bags. Customers can gently manipulate and massage the bag to move the air to the top of the bag near the ports. The bag may need to be tilted to get the air to move near the port and then the user can pull out the air using the syringe.

What particulate matter testing is performed and what is the acceptance criteria?

Your account representative can provide you with a detailed summary of particulate inspections performed on OriGen Biomedical® products [TCL03]. Please reach out to them directly.

How much air is acceptable to be left in the bag when undergoing cryopreservation?

OriGen recommends removing as much air as possible since multiple small air bubbles can combine and form one large air bubble. If air is left in the bag, the air can rapidly expand and the pressure can result in bag breaks. We do not have a quantitative amount of air defined as acceptable within the bag and recommend users follow their institutional protocols and validate their processes.

What cleaning solutions can be used with OriGen Biomedical products?

OriGen uses 70% IPA in our production environment, including wiping S-F10 accessory sets. There are no expected adverse impacts to using a wipe moistened with 70% IPA to wipe the sets. We have not validated that 70% IPA disinfects the sets.

What are your pouching materials?

Our pouches are made of Tyvek (white side) and PET/LDPE (clear side).

Is it okay to use the CryoStore Freezing Bag if some of the components have changed color?

Some of the plastic components discolor overtime due to the gamma radiation used in sterilization. This is expected and has been show to not affect the performance of the device. However, please report a complaint to OriGen if something discolors differently than expected. For example, if there is a large difference in color/shade between similar components in the same lot, similar components in different lots, or components within the same packaging.

Kim GH, Patel N, Reich-Slotky R. How do I save cell therapy product’s storage space? Transfusion. 2023 Apr;63(4):679-683. doi: 10.1111/trf.17294. Epub 2023 Feb 25. PMID: 36840439.